On a PV module, which symbol represents the Maximum Peak output Power.
Wp
Isc
Vmpp
Voc
On a PV module, which symbol represents the 'open circuit voltage'.
Wp
Isc
Vmpp
Voc
On a PV module, which symbol represents the 'peak power voltage'.
Wp
Isc
Voc
Vmpp
On a PV module, which symbol represents the 'short-circuit current'.
Wp
Impp
Voc
Isc
A PV module Specifications shows 1000 watts per metre square, AM: 1.5, 25 degrees. These are the STC values, What does STC mean?
Standard Test Conditions
Solar Test Criteria
Special Terminal Connections
Specific Type (of) Construction
A PV module Specifications shows 1000 watts per metre square, AM=1.5, temp=25 degrees. These are the STC values, What does 'AM' mean?
Air Mass
Amps Measurement
Ambient Moisture
Automatically Maintained
Two PV modules have a voltage of 12v and a current capacity of 10 A each. If they are connected is parallel what would the Total voltage be?
24v
12v
22v
2v
Two PV modules have a voltage of 12v and a current capacity of 10 A each. If they are connected is Series what would the Total voltage be?
24v
12v
22v
2v
Two PV modifies have a voltage of 12v and a current capacity of 10 A each. If they are connected is Series what would the Total current capacity value be?
10A
20A
120A
2A
Two PV modules have a voltage of 12v and a current capacity of 10 A each. If they are connected in Parallel what would the Total current capacity be?
20A
10A
120A
2A
A single PV module is rated at 24V@8A. Calculate the Power that the module could deliver.
192 watts
32 watts
3 watts
135 watts
A single PV module is rated at 48V@12A. Calculate the Power that the module could deliver.
576 watts
60 watts
3 watts
99 watts
To achieve a total voltage of 200v from individual PV modules rated at 25v@15 A, how many modules would be required when connected in series ?
8
4
10
25
To achieve a total current of 45A from individual PV modules rated at 25v@15 A, how many modules would be required when connected in parallel?
3
1
10
2
a PV string, delivers 48V at 15A. Calculate the total power that can be delivered by the PV string..
63 watts
720 watts
192 watts
100 watts
Four PV strings rated 12V at 12A each, are connected in parallel. Calculate the total current that can be delivered.
12 Amps
48 Amps
24 Amps
48 Amps
If two 25 watt lamps are used for 5 hours per day and a 65 watt fan is used for 7 hours per day. Calculate the Total appliance power requirements for a 24 hour period, for a proposed PV installation.
705 Wh/day
580 Wh/day
880 Wh/day
455 Wh/day
If two 60 watt lamps are used for 8 hours per day, a 65 watt fridge is used for 7 hours per day and a 60 watt fire alarm system is permanently powered, Calculate the Total appliance power requirements for a 24 hour period, for a proposed PV installation.
2.86 kWh/day
5.80 kWh/day
4.86 kWh/day
1.55 kWh/day
From which direction does the sun rise in the morning?
North
South
East
West
In which direction does the sun set in the evening?
North
South
East
West
In the UK the position of the sun (angle) changes by up to 46 degrees through the year. At what optimum angle should a FIXED PV array be installed to make the most use of the available sunlight.
20 degrees
35 degrees
50 degrees
60 degrees
When siting PV arrays in the UK, which direction should they face to make the most use of the available sunlight?