Based on C&G2382 - BS7671:2018 (Amendment 2:2022) Electrical Regulations revision
use BS7671 Amendment 2:2022 regulations book - all sections. 12 random questions from a large bank of questions (references to regulations when necessary are given with correct answers).
BS7671:Amendment 2:2022 is which one of the following
non-statutory publication
statutory publication
publication designed only for the use of electricians
publication used only for the design of new electrical installations
The fundamental principles of BS7671 states that persons and livestock shall be protected against injury caused by overvoltages that originate from
atmospheric events
generation of voltage
electrical equipment that is on
faulty circuits
The fundamental principles of BS7671 states that protection against voltage disturbance in an installation shall have an adequate level of immunity against
electromagnetic disturbance
loss of voltage
low circuit loading
excessive vibration
Identify the maximum calculated Zs value of a C-type circuit breaker
2.19 ohms
1.15 ohms
1.44 ohms
3.45 ohms
Define en electric hair-dryer which is 'double insulated'
class II
class I
class V
band 2
An electrical installation certificate should only be signed by whom
competent person
local authority
customer
supply authority
Regarding External Influences, identify the protection offered by code AD4
IPx4
IPx0
IPx3
IPx5
Regarding External Influences, identify the protection offered by code AD1
IPx0
IPx4
IPx3
IPx5
Regarding External Influences, identify the ambient temperature range offered by code AA5
+5 to +40 degrees C
-10 to + 25 degrees C
-25 to + 35 degrees C
+10 to +40 degrees C
Regarding External Influences, identify the ambient temperature range offered by code AA1
-60 to +5 degrees C
+10 to + 25 degrees C
-25 to + 35 degrees C
+10 to +40 degrees C
BS7671 states that 'electrical installation shall be divided into circuits to'
reduce electromagnetic disturbance
facilitate easier access for testing
enable equal distribution of power
minimise electrical faults
Identify the point of measurement for determination of the External Impedance (Ze) of an installation
at the origin
at the furthest point
after the distribution board
at the mid-point
The maximum disconnection time for a 230v A.C final circuit on a TN system that does not exceed 32A is
0.4 secs
1 sec
5 secs
0.2 secs
The maximum calculated Zs value for a 16A type 'B' circuit breaker is
3.73 ohms
1.44 ohms
0.88 ohms
5.97 ohms
Undervoltage protection is required when the restoration of the electrical supply following a power cut could cause
unexpected start up of machinery
circuit overloads
nuisance tripping of protective devices
high start up currents
Identify the device that cuts off all or part of an installation from every source of electrical supply
isolator
switch
fireman’s switch
emergency switching
The maximum calculated Zs value for a 32A type 'B' circuit breaker protecting a standard A1 ring circuit is
1.37 ohms
1.44 ohms
0.88 ohms
0.44 ohms
For a TT installation, distribution circuits shall have a maximum disconnection time of
1 sec
5 secs
0.2 secs
0.4 secs
Identify the operation characteristics of a Residual current device (RCD)
a magnetic device that operates due to current imbalance between L and N
a magnetic device that operates due to a fault between L and N
a bi-metal device that operates due to current imbalance between L and E
a bi-metal device that operates due to a fault between L and E
a RCBO can protect against which one of the following fault(s)
short circuit, overload and earth leakage
overload only
earth leakage faults only
short circuits only
a RCCB can protect against which one of the following fault(s)
earth leakage but not designed for short circuit and/or overload
overloads only
short circuit, overload and earth leakage
short circuits only
in AC systems, in the event of basic insulation failing additional protection can be provided by use of
RCD rated at 30mA
RCD rated at 100mA
supplementary bonding
electrical separation
Nuisance tripping that could be caused by switching large Inductive loads can be eliminated by the use of
type D MCB
type B MCB
30mA RCD
100mA RCBO
If a conductor is buried less than 50mm in a wall and not protected by an earthed metallic enclosure, additional protection is provided by
30mA RCD
MCB
supplementary bonding
functional earth conductor
Which one of the following would not require the fitting of a label of notice
copper water pipe
bonded gas main pipe
earthing terminal within a consumers unit
earth electrode
When calculation the Tabulated current for a circuit, the correction factor applicable to a BS3036 fuse is
0.725
0.88
0.94
1
a BS1362 protective devise is also known as
cartridge fuse
semi-enclosed fuse
HRC fuse
RCCB
An installation protected by a RCD shall have a fixed notice that includes
test at 6 monthly intervals
test occasionally
test at 3 monthly intervals
test monthly
An insulated PEN conductor is identified by
green/yellow insulation with blue markings at the terminations
blue insulation along its length
green/yellow insulation along its length
green insulation with blue markings at the terminations
Where a generating set is used as an alternative parallel source of supply, it needs to be installed
on the supply side of all protective devices for the final circuits of the installation with no additional requirements
on the supply side of all protective devices for the final circuits of the installation with additional requirements in place
on the load side of all protective devices for the final circuits of the installation with no additional requirements
on the load side of all protective devices for the final circuits of the installation with additional requirements in place
With regard to auxiliary supplies to safety supply services, maximum changeover time refers to
the time taken for the safety source to supply power to the safety service after a break in the main power supply
the length of time that the safety service can remain powered up once the changeover has occurred
the delay time required before the changeover is allowed to occur
the total time that the safety service can remain powered by the auxiliary supply
The minimum insulation resistance value allowable for a SELV installation is
0.5M ohms
1M ohms
0.25M ohms
2M ohms
The minimum insulation resistance value allowable for a PELV installation is
0.5M ohms
1M ohms
0.25M ohms
2M ohms
During initial verification of an installation, which one of the following will form part of the inspection checklist
presence of diagrams and instructions
maximum demand of the installation
design specifications
diversity allowances
what is measured during a total earth fault loop impedance test on an A1 ring circuit
the resistance of the line and protective conductors in the ring plus the external impedance
the resistance of the line and neutral conductors in the ring plus the external impedance
the resistance of the line and protective conductors only in the ring
only the protective conductor resistance
the purpose of a polarity test is to verify
every fuse and single-pole device is installed in the line conductor only
protective devices are adequate for the circuit
conductor insulation is in good order throughout
neutral conductors are switching correctly
In an agricultural installation the bonding conductors should be
4mm sq copper
6mm sq copper
10mm sq aluminium
16mm sq aluminium
Suspended cables between buildings on an agricultural installation should be at least how high above ground level
6m
5m
4m
10m
electrical equipment installed within zone 2 of an outdoor swimming pool where no water jets are used should be protected to
IPX4
IP2X
IPXXB
IPX8
if SELV is used in an agricultural premises, barriers and enclosures need to offer a protection level of
IPXXB
IP4X
IPX5
IP65
in an area that contains a bath or shower, socket outlets are allowed to be installed at least
2.5m horizontally from boundary of zone 1
3m horizontally from of zone 2
3m horizontally from boundary of zone 1
2.5m from boundary of zone zero
the floor temperature of underfloor heating, where contact with footwear of skin is likely, must be limited to
35 degrees C
40 degrees C
20 degrees C
50 degrees C
a mobile unit should have an electrical connection between
vehicle chassis and the main earthing terminal
neutral and main earth terminal
neutral and earth electrode
vehicle chassis and supply neutral
the preferred type of insulation on the DC side of a PV installation is
class II
class I
type 3
type 1
in areas not subjected to vehicular movement in a marina, overhead cables shall be installed at a minimum height of
3.5m
4m
5.5m
6m
in areas not subjected to vehicular movement in a caravan park, overhead cables shall be installed at a minimum height of
3.5m
4m
5.5m
6m
BS 5839 details the requirements for
fire alarms
emergency lighting
switching devices
discharge lighting
BS 5266 details the requirements for
emergency lighting
intruder alarms
isolation devices
supply transformers
identify the correction factor for three multicore cables installed as a single-layer on a wall
0.79
0.82
0.77
0.65
Equipment intended for use as life support within a patient environment in a Group 2 medical location forming part of an IT system, excludes which one of the following types of
X-ray equipment
surgical application equipment
all equipment with low power rating
freezer equipment
Choice of wiring type and method of installation shall condider all except for
load current
nature of the location
voltage level
short circuit current values
Identify the location not recognised as a special location within BS7671
Fireworks factory
marinas
saunas
gangways
A component of a support system consisting of elements which are regularly speced and mechanically retains a cable is called a cable..
cleat
clip
retainer
bracket
Maintainablity should be considered when assessing
reliability of equipment
repair costs
repair time
installation scheduling
PME (protective multiple earthing) is also known as
TN-C-S
TN-C
TN-S
TT
Buildings with a shape and dimensions which could facilitate the spread of fire have which classification
CB2
CA1
BE2
CA2
When more than one transformer is used to supply an auxiliary circuit it should be connected
in parallel on both primary and secondary sides
in series on both primary and secondary sides
with only the primary sides in parallel
with only the secondary sides in parallel
Gangways with closed restriced access shall be accessible by doors from oth ends when gangways are longer than
20m
10m
15m
18m
For a Low voltage Prosumer installation, PEI concept excludes which one of the following
UPS systems
public power supply
heating systems
energy management
For a Low voltage Prosumer Electrical Installations, which one of the following is not recognised as a general type of PEI