identify the maximum Continuity value for Equipotential Bonding conductors as recommended by BS7671
0.25 ohms
0.5 ohms
1 ohm
0.05 ohms
identify the information you should have available before the inspection and test of a new installation
external loop impedance
r1+r2 circuit values
total fault loop impedance
RCD disconnection times
identify the most appropriate method to ensure a circuit is safe to start work on
use a GS38 voltage indicating device
switch off the circuit MCB
open the main switch
safe isolation procedure
an 'Electrical Installation Condition Report' is completed for which one of the following
new electrical installation
fully refurbished property
existing electrical installation
replacement distribution board
identify the appropriate sense used to detect an overloaded socket outlet
sight
taste
hearing
touch
the 'rule of thumb' for 3-phase Ipsc states that it will be approximately
twice the value of the single-phase value
three times the value of the single-phase value
66% of the single-phase value
1/3rd of the single-phase value
the combination of Earth Electrode resistance and the rating of the RCD should not exceed which voltage when concerning a Construction site
230v AC
50v AC
25v AC
110v AC
identify the disconnection time requirement for a BS61009 RCBO rated at 30mA when tested at x1
within 400mS
within 100mS
within 200mS
within 300mS
identify the test voltage for Insulation Resistance for a 400v AC 3-phase circuit
250v
500v
750v
1000v
identify the maximum disconnection time requirement for a 'time-dalayed' BS61009 RCBO rated at 30mA
40mS
200mS
500mS
300mS
identify the IP requirement for the sides of a circuit distribution board
IP4x
IPx4
IP2x
IPx2
a radial circuit is 24m long and installed with 4.0 mmsq single-core conductors. The Ze for the installation is 0.44 ohms. The On Site Guide gives a Resistivity value of 4.61m Ohms/metre for a 4.0 mmsq conductor at 20 degrees C. Calculate the Zs value for the circuit
0.48 ohms
0.5 ohms
0.66 ohms
0.72 ohms
identify the location to take a correct reading for Total Earth Fault Loop Impedance
at the beginning of the circuit
at the remote part of the circuit
at the mid-point in the circuit
at the origin of the circuit
if the cross-sectional area (c.s.a) of a conductor decreases and its length remains the same, its resistance will
increase
decrease
remain the same
reduce to zero
carrying out a Total Earth fault Loop Impedance test on an A1 Ring circuit can be best accomplished with the availability of
a BS1363 accessory
the previous test results
a set of shorting leads
a 'wander lead'
when measuring Total Earth Fault Loop Impedance on live circuit, results can quickly be verified by comparing results with...
values in BS7671 regulations book tables
values in previous schedule of test results
values in BS7671 On Site Guide tables
values provided by the installation designer
identify the easiest method of determining correct Polarity on an A1 Ring circuit
during (r2) continuity test
during dedicated polarity test
during continuity of ring test
during total earth fault loop impedance test
identify the easiest method of determining correct Polarity on a lighting circuit
during (r2) continuity test
during dedicated polarity test
during continuity of ring test
during total earth fault loop impedance test
identify the test used to determine that 'every protective device and single pole switch is connected in the Line conductor'
insulation resistance
loop impedance
continuity
polarity
identify the appropriate human sense to detect overheating windings in a 230v motor
hearing
smell
taste
sight
protective devices for installed circuit must have a maximum breaking capacity of at least
10kA
twice the circuit rating
the max Ipsc for the circuit
1kA
identify the test voltage for Insulation Resistance test on a SELV circuit
250v
500v
230v
1000v
identify the test voltage for Insulation Resistance test on a 230v AC circuit
250v
500v
400v
1000v
identity the consequence of leaving lighting loads connected during an Insulation Resistance test
damage to the test instrument
possible circuit damage
false test readings
electric shock risk
identify the main purpose of conducting a Continuity of Ring Final Circuits test with a low-ohms tester
to provide accurate results
to prove the integrity of the circuit
to ensure sufficient range of results
to ensure it is safe to use
if the cross-sectional area (c.s.a) of a conductor increases and its length remains the same, its resistance will
decrease
remain the same
increase
settle at zero
if the cross-sectional area (c.s.a) of a conductor remains the same but its length reduces, its resistance will
increase
decrease
remain the same
reduce to zero
if the cross-sectional area (c.s.a) of a conductor remains the same but its length increases, its resistance will
increase
decrease
remain the same
reduce to zero
identify the appropriate sense used to detect a loose live electrical connection
sight
taste
hearing
touch
The EaW 1989 (Electricity at Work regulations) has some regulations that are reasonable practicable and others that are absolute. identify the meaning of the 'reasonably practicable' requirements
the specific regulation is correct
the specific regulation must be met
the specific regulation must be met within a certain time
the specific regulation should be actioned if it can
an A1 Ring continuity test shows 0.6 ohms (end-to-end) for Line and neutral conductors with c.p.c (end-to-end) showing 1 ohm. Identify the expected reading between Line and neutral at each socket outlet on the Ring.
1.6 ohms
0.4 ohms
0.3 ohms
1.2 ohms
identify the disconnection time requirement for a BS61009 RCBO rated at 30mA when tested at x0.5
within 150mS
should not disconnect
within 40mS
within 300mS
identify the IP requirement for the top surface of a circuit distribution board
IPx2
IPx4
IP2x
IP4x
when conducting a Ze test, the installation main Earthing conductor should be
left connected
connected to an earth electrode
disconnected
connected to all bonding
an installation Fault Current test shows Ipfc = 1.8kA and Ipscc = 2.1kA. What is recorded on the test document
the sum of both readings
the lowest reading
the highest reading
the average of the two readings
when carrying out RCD testing it is a requirement to operate the test button. Identify the purpose of this specific requirement
to verify the mechanical operation
to verify the RCD sensitivity
to verify its automatic disconnection
to ensure the circuit is isolated
before carrying out 'live' testing of an installation, you must
isolate the mains supply at the origin
remove all protective devices
inform other people who are in the area
remove all accessory covers
when conducting Insulation Resistance testing of an intermediate lighting circuit, it is important to
ensure all switches are in the ON position
operate all switches during the test
link out the switches with a shorting lead
set the switches to the off position
before conducting an Insulation Resistance test it is important to
link Line and c.p.c in the fuse board
remove any sensitive electronic loads from the circuit
disconnect the c.p.c from the circuit
ensure loads are installed
BS7671 states that the minimum Insulation Resistance value for a 230v AC circuit must be no less than
2M ohms
1M ohms
0.5M ohm
200M ohm
BS7671 regulations book details 'calculated' Zs values in tables. As a rule of thumb, 'measured' values of Zs should be
no higher than calculated values
80% of calculated values
higher than calculated values
the same
an A1 Ring continuity test shows 0.5 ohms (end-to-end) for each Line and neutral conductor and the c.p.c (end-to-end) recorded at 0.84 ohms. Identify the expected (r1+r2) reading between Line and c.p.c at each socket outlet on the Ring.
1.34 ohms
0.4 ohms
0.34 ohms
0.62 ohms
'wire of solid objects greater than 1mm in diameter' have the IP code of
IPx2
IPx4
IP4x
IP2x
The EaW 1989 (Electricity at Work regulations) has some regulations that are reasonable practicable and others that are absolute. identify the meaning of the 'absolute' requirements
the specific regulation is correct
the specific regulation must be met
the specific regulation is non statutory
the specific regulation meets BS7671
a completed Electrical Installation certificate will identify the responsibility for
the materials and construction methods used
the design, environmental conditions and inspection and testing
the design, construction and inspection and testing
the installation, ownership and construction
a completed Electrical Installation Certificate will only be signed by
the local council authority
someone with a part 'P' qualification
the installation designer
a competent person
an extra lighting point is installed as part of an existing electrical installation. When completed identify which one of the following should be issued
electrical installation certificate
electrical installation condition report
periodic inspection report
minor works certificate
when a Minor Works certificate is to be issues for a modified circuit. Identify which one of the following details regarding the protective device should be recorded on the certificate
device BS(EN) number and rating
device rating and disconnection time
device manufacturer and Ipscc
device Ipscc and disconnection time
from the following selections, identify the information you should have available to you prior to starting the Inspection and Testing of a new installation
the maximum demand per phase
the polarity information of the supply
the name of the Regional Electricity Company (REC)
the name of the customer
an existing installation on a TN-C-S system of Earthing has 6 circuit protected by BS3036 protective devices and a measured Ze value of 0.08 ohms. Identify the reason why this could be potentially dangerous
the BS3036 devices are not permitted on TN-C-S systems
the resultant Ipfc may be too high for adequate circuit protection